PROTEC GAS

X-am 5100 H2O2, HBr, HCl, HF, HNO3, N2H4, PCl3 or POCl3 gas detector

X-am 5100 H2O2, HBr, HCl, HF, HNO3, N2H4, PCl3 or POCl3 gas detector

Regular price $1,698.00
Regular price Sale price $1,698.00
Sale Sold out

The X-am 5100 single gas detector assets

The Dräger X-am 5100 gas detector is a portable single gas detector for H2O2, HBr, HCl, HF, HNO3, N2H4, PCl3 or POCl3 monitoring. It provides continuous, accurate and reliable measurement in the fields of petroleum product manufacturing, sanitary packaging, corrosion protection or space production.

  • Light, robust (insensitive to shocks, shakes and electromagnetic radiation) and practical (portable hand-held format)
  • Triple Alarm: Visual (360 °), Audible (Multi-tones) and Vibrating
  • Very easy to use: Only two keys

Gases detected by the X-am 5100 monitor

Sensor Gas Formula CAS Measuring range Relative sensibility
H2O2  Hydrogen peroxide  H2O2 7722-84-1 0-20 ppm -
N2H4  Hydrazine  N2H4 302-01-2 0-5 ppm -
HCL Hydrogen chloride HCL 7647-01-0 0-30 ppm 1.00
HCL Nitric acid HNO3 7697-37-2  0-30 ppm 1.00
HCL Hydrogen bromide  HBr 10035-10-6  0-30 ppm 1.00
HCL Phosphoryl chloride  POCl3 10025-87-3 0-30 ppm 1.00
HCL Phosphorus trichloride  PCl3 7719-12-2 0-30 ppm 3.00
HCL Hydrogen fluoride  HF 7664-39-3 0-30 ppm  0.66

Dräger X-am 5100 detector technical specifications

  • H2O2 sensor measuring range: 0-20 ppm
  • N2H4 sensor measuring range: 0-5.0 ppm
  • Measuring range / relative sensitivity (HCl sensor) :
    - 0 to 30 ppm HCl (hydrochloric acid) / 1.00
    - 0 to 30 ppm HNO3 (nitric acid) / 1.00
    - 0 to 30 ppm HBr (hydrogen bromide) / 1.00
    - 0 to 30 ppm POCl3 (phosphryl chloride) / 1.00
    - 0 to 30 ppm PCl3 (phosphorus trichloride) / 3.00
    - 0 to 30 ppm HF (hydrogen fluoride) / 0.66
  • Detection limit : 1 ppm / Resolution : 0.1 ppm
  • Temperature : –20 to +50 / Pressure : 700 to 1 300 / Humidity : 10 to 95 % H. R.
  • Protection : IP 54
  • Alarms : - Visual : 180° / Sound : multi-tones > 90 dB à 30 cm & vibrating
  • Battery life (h) : > 200 / Charging time (h) : <4
  • Compatible sensors : XS H2O2, XS Hydrazine, XS HF/HCL
  • Data logger: retrivable using an infrared interface > 1000h at a recording interval of 1 value per minute
  • Dimensions (l × h × p) : 47 x 129 x 55 mm / Poids : 220 g
  • Certifications :
    - ATEX : IM1ExiaIMa II 1G Ex ia IIC T4/T3 Ga
    - IECEx : ExiaIMa Ex ia IIC T4/T3 Ga
    - CSA us : Class I, Div. 1, Groups A, B, C, D TC T4/T3 Class I, Zone 0, A/Ex ia IIC T4/T3 /Ga
  • CE marking: Electromagnetic compatibility (Guideline 2004/108/EC)

The X-am 5100 associated to the X-zone 5500 area gas monitor

The X-zone 5500 area gas monitor transforms the X-am 510 gas detector 0 into a powerful, innovative zone monitoring device (also called construction site area monitor) and suitable for many applications.

A patented combination for increased safety: in addition to portable devices for individual monitoring, these area monitoring devices are placed where dangerous gases are likely to be present .

View full details