{"product_id":"fixed-hydrogen-chloride-hcl-gas-detector-0-to-10-20-50-100-200-ppm","title":"Fixed Hydrogen Chloride (HCl) Gas Detector, 0 to 10\/20\/50\/100\/200 ppm","description":"\u003cdiv class=\"short-description\"\u003eFavorable price HCl hydrogen chloride gas detector with alarm light is a 24h continuously wall mounted type gas detector which can detect HCL in different kinds of situations. Measuring range 0 to 10\/20\/50\/100\/200 ppm, powered by 24V DC, with 4-20mA, RS485, relay signal output.\u003c\/div\u003e\n\u003cdiv class=\"attributes\"\u003e\n\u003cdl\u003e\u003c\/dl\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003eATO fixed HCL hydrogen chloride gas detector uses high quality sensors, and advanced micro-process technology, with data display and high\/low alarm, fast response, high precision and good stability. Explosion proof, suitable for different kinds of situations.\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003cbr\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"30%\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"70%\"\u003eGD300-HCL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Principle\u003c\/td\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas\u003c\/td\u003e\n\u003ctd\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (Optional)\u003c\/td\u003e\n\u003ctd\u003e0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 200ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01ppm (0-10\/20\/50ppm), 0.1ppm (0-100\/200ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Kit\u003c\/td\u003e\n\u003ctd\u003eGas pressure regulator (calibration gas cylinder NOT included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e≤±3% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e≤10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e≤±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery Time\u003c\/td\u003e\n\u003ctd\u003e≤10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e≤±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Shift\u003c\/td\u003e\n\u003ctd\u003e≤±1% (F.S.\/year)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output (Optional)\u003c\/td\u003e\n\u003ctd\u003e4-20mA and RS485\u003cbr\u003eRelay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high\/low alarm (optional).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms\u003c\/td\u003e\n\u003ctd\u003eSound, light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eHigh light nixie tube display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, piping type, flow-type (according to the detected environment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003ePower connection type: G1\/2 male thread explosion-proof flexible pipe\u003cbr\u003ePipe-mounted type: M45*P2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003e24h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion-proof Grade\u003c\/td\u003e\n\u003ctd\u003eⅡ 2G Ex ia Ⅱ CT4 Ga\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Grade\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e12-36V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eDie-casting aluminum housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20℃~50℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0~95%RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension\u003c\/td\u003e\n\u003ctd\u003e206*179*90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≤1.6kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003ePower adapter: Input 100-240VAC 50\/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eFixed Gas Detector Dimension (Unit: mm)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/www.ato.com\/Content\/Images\/uploaded\/Fixed-gas-detector-with-alarm-dimension.jpg\" alt=\"Fixed gas detector with alarm dimension\" width=\"718\" height=\"524\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e***Other Common Gases and Ranges Available for Fixed Gas Detectors\u003cbr\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-ammonia-nh3-gas-detector\"\u003eAmmonia (NH3)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-50\/100\/200\/500\/1000\/2000\/5000ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-c6h6-gas-detector\"\u003eBenzene (C6H6)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/10\/50\/100\/200\/1000\/2000\/5000\/10000ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-carbon-dioxide-co2-gas-detector\"\u003eCarbon Dioxide (CO2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1000\/2000\/5000\/9999ppm, 0-2\/5\/10\/20\/25\/30\/50\/100%VOL\u003c\/td\u003e\n\u003ctd\u003e0.1ppm\/1ppm\/0.001%VOL\/0.01%VOL\/0.1%VOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-carbon-monoxide-co-gas-detector\"\u003eCarbon Monoxide (CO)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/50\/100\/500\/1000\/2000ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-cl2-gas-detector\"\u003eChlorine (Cl2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5\/10\/20\/50\/100ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-clo2-gas-detector\"\u003eChlorine Dioxide (ClO2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-combustible-gas-detector\"\u003eCombustible Gas (EX)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%LEL\u003c\/td\u003e\n\u003ctd\u003e1%LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-c2h4-gas-detector\"\u003eEthylene (C2H4)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/50\/100\/500\/1000\/2000ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-formaldehyde-gas-detector\"\u003eFormaldehyde (CH2O)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/50\/100\/500\/1000ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-hc-gas-detector\"\u003eHydrocarbons (HC)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100%LEL\u003c\/td\u003e\n\u003ctd\u003e1%LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-hydrogen-h2-gas-detector\"\u003eHydrogen (H2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/500\/1000\/2000\/5000\/9999ppm, 0-2\/4% VOL, 0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e0.1ppm\/1ppm\/0.001%VOL\/1%LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-hcl-gas-detector\"\u003eHydrogen Chloride (HCL)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/50\/100\/200ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-hcn-gas-detector\"\u003eHydrogen Cyanide (HCN)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/50\/100ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-hydrogen-sulfide-h2s-gas-detector\"\u003eHydrogen Sulfide (H2S)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5\/20\/50\/100\/200ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-methane-ch4-gas-detector\"\u003eMethane (CH4)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-50\/100%VOL, 0-100%LEL\u003c\/td\u003e\n\u003ctd\u003e0.01%VOL\/0.1%VOL\/1%LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-no-gas-detector\"\u003eNitric Oxide (NO)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100\/250\/500\/1000ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-nitrogen-n2-gas-detector\"\u003eNitrogen (N2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-99.99\/0-100%VOL\u003c\/td\u003e\n\u003ctd\u003e0.01%VOL\/0.1%VOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-no2-gas-detector\"\u003eNitrogen Dioxide (NO2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100\/500\/1000ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-nox-gas-detector\"\u003eNitrogen Oxides (NOX)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100\/250\/500\/1000ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-oxygen-o2-gas-detector\"\u003eOxygen (O2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-25\/30\/100%VOL\u003c\/td\u003e\n\u003ctd\u003e0.01%VOL\/0.1%VOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-ozone-o3-gas-detector\"\u003eOzone (O3)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-ph3-gas-detector\"\u003ePhosphine (PH3)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10\/20\/50\/100\/500\/1000\/2000\/3000ppm\u003c\/td\u003e\n\u003ctd\u003e0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-so2-gas-detector\"\u003eSulfur Dioxide (SO2)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100\/500\/1000ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ato.com\/fixed-voc-gas-detector\"\u003eVolatile Organic Compounds (VOC)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1\/5\/10\/20\/50\/100\/200\/500\/1000\/2000\/5000\/10000ppm\u003c\/td\u003e\n\u003ctd\u003e0.001ppm\/0.01ppm\/0.1ppm\/1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"PROTEC GAS","offers":[{"title":"Default Title","offer_id":42771108298829,"sku":null,"price":1062.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/9089\/0829\/files\/Screenshot2026-03-10195037.png?v=1773193932","url":"https:\/\/protecgas.com\/products\/fixed-hydrogen-chloride-hcl-gas-detector-0-to-10-20-50-100-200-ppm","provider":"PROTEC GAS","version":"1.0","type":"link"}